# Database for variable names, default values, allowed minimum, maximum, and graphing default min and max.
#
# These are simulation parameters (Independent variables)
#
#	:Place	:Device	:Type 	:Dep/Ind:Default:Min	:Max	:Gmin	:Gmax	:Name
#-------:-------:-------:-------:-------:-------:-------:-------:-------:-------:--------------------------------
	:l	:vcap	:csys	:i	:0.4	:0.2	:20.0	:0.0	:2.0	:LV Min. Systolic Capacitance
	:r	:vcap	:csys	:i	:1.2	:0.2	:40.0	:0.0	:4.0	:RV Min. Systolic Capacitance

	:l	:vcap	:cdias	:i	:10.0	:0.2	:20.0	:0.0	:20.0	:LV Max. Diastolic Capacitance
	:r	:vcap	:cdias	:i	:20.0	:0.2	:40.0	:0.0	:40.0	:RV Max. Diastolic Capacitance

	:a	:cap	:cap	:i	:1.6	:0.1	:20.0	:0.0	:6.0	:Arterial Capacitance
	:pa	:cap	:cap	:i	:4.3	:0.1	:20.0	:0.0	:6.0	:Pulmonary Artery Capacitance
	:v	:cap	:cap	:i	:100.0	:0.1	:500.0	:0.0	:200.0	:Venous Capacitance
	:pv	:cap	:cap	:i	:8.4	:0.1	:40.0	:0.0	:20.0	:Pulmonary Venous Capacitance

	:l	:vcap	:zvol	:i	:15.0	:0.0	:1000.0	:0.0	:30.0	:LV Zero-Pressure Volume
	:r	:vcap	:zvol	:i	:15.0	:0.0	:1000.0	:0.0	:30.0	:RV Zero-Pressure Volume
	:a	:cap	:zvol	:i	:715.0	:0.0	:5000.0 :0.0	:1500.0	:Arterial Zero-Pressure Volume
	:pa	:cap	:zvol	:i	:90.0	:0.0	:5000.0	:0.0	:200.0	:Pulm. Art. Zero-Pressure Volume
	:v	:cap	:zvol	:i	:2500.0	:0.0	:10000.0:0.0	:5000.0	:Venous Zero-Pressure Volume
	:pv	:cap	:zvol	:i	:490.0	:0.0	:5000.0	:0.0	:1000.0	:Pulm. Ven. Zero-Pressure Volume

	:l	:res	:res	:i	:0.006	:0.004	:2.0	:0.0	:0.01	:LV Outflow Resistance
	:r 	:res	:res	:i	:0.003	:0.0001	:2.0	:0.0	:0.01	:RV Outflow Resistance
	:micro	:res	:res	:i	:1.0	:0.0001	:10.0	:0.0	:5.0	:Arteriolar Resistance
	:pmicro	:res	:res	:i	:0.08	:0.0001	:2.0	:0.0	:0.1	:Pulmonary Vascular Resistance
	:v	:res	:res	:i	:0.05	:0.0001	:2.0	:0.0	:0.1	:Venous Resistance
	:pv	:res	:res	:i	:0.010	:0.0005	:2.0	:0.0	:0.1	:Left Heart Inflow Resistance

	:sys	:system	:hr	:i	:72	:10.0	:250.0	:50.0	:150.0	:Heart Rate
	:sys	:system	:volume	:i	:5000.0	:100.0	:10000.0:0.0	:10000.0:Total Blood Volume
	:sys	:system	:pressure:i	:-4.0	:-50.0	:50.0	:-10.0	:10.0	:Pulmonary Trans-Thoracic Pressure

# These are all Dependent (computed) variables
#
#	:Place	:Device	:Type 	:Dep/Ind:Default:Min	:Max	:Gmin	:Gmax	:Name
#-------:-------:-------:-------:-------:-------:-------:-------:-------:-------:--------------------------------
	:l	:vcap	:pressure:d	:0	:-100	:500	:0.0	:150.0	:LV Pressure
	:r	:vcap	:pressure:d	:0	:-100	:500	:-10.0	:30.0	:RV Pressure
	:a	:cap	:pressure:d	:0	:-100	:500	:0.0	:150.0	:Systemic Arterial Pressure
	:pa	:cap	:pressure:d	:0	:-100	:500	:-10.0	:30.0	:Pulmonary Arterial Pressure
	:v	:cap	:pressure:d	:0	:-100	:500	:0.0	:20.0	:Systemic Venous Pressure
	:pv	:cap	:pressure:d	:0	:-100	:500	:0.0	:20.0	:Pulmonary Venous Pressure

	:l	:vcap	:volume	:d	:0	:0	:5000	:0.0	:200.0	:LV Volume
	:r	:vcap	:volume	:d	:0	:0	:5000	:0.0	:200.0	:RV Volume
	:a	:cap	:volume	:d	:0	:0	:5000	:700.0	:1000.0	:Systemic Arterial Volume
	:pa	:cap	:volume	:d	:0	:0	:5000	:100.0	:300.0	:Pulmonary Arterial Volume
	:v	:cap	:volume	:d	:0	:0	:5000	:3100.0	:3250.0	:Systemic Venous Volume
	:pv	:cap	:volume	:d	:0	:0	:5000	:500.0	:750.0	:Pulmonary Venous Volume

	:l	:res	:flow	:d	:0	:0	:10000	:-100.0	:2000	:LV Outflow
	:r	:res	:flow	:d	:0	:0	:10000	:-100.0	:2000	:RV Outflow
	:micro	:res	:flow	:d	:0	:0	:10000	:0.0	:200	:Systemic Microcirculatory Flow
	:pmicro	:res	:flow	:d	:0	:0	:10000	:0.0	:200	:Pulmonary Microcirculatory Flow
	:v	:res	:flow	:d	:0	:0	:10000	:-100.0	:200	:RV Inflow
	:pv	:res	:flow	:d	:0	:0	:10000	:-100.0	:1000	:LV Inflow

	:l	:vcap	:cap	:d	:0	:0	:10000	:0.0	:10.0	:LV Instantaneous Capacitance
	:r	:vcap	:cap	:d	:0	:0	:10000	:0.0	:20.0	:RV Instantaneous Capacitance
	:v	:res	:cdias	:d	:0	:-100	:500	:-10	:20.0	:Right Atrial Pressure
	:pv	:res	:cdias	:d	:0	:-100	:500	:0.0	:20.0	:Left Atrial Pressure

        :sys    :system	:time   :d      :0.0    :0.0    :9999999:0.0    :5.0    :Time